Sale!

Blue Water 900 Hydrogen Water and Gas Generator

$495.00 $395.00

Blue Water 900 is a best in class 2 in 1 hydrogen generator/hydrogen gas inhaler in the design of a sports bottle. It produces hydrogen rich water and generates hydrogen gas which can be consumed through an inhaler . The uniqueness of Blue Water 900 lies in its compact size, ease of use and the advanced technology. Blue Water 900 is powered by a long lasting lithium battery. The base of Blue Water 900 is equipped with a Platinium and Titanium plated electrode and PEM (Proton Exchange Membrane) technology to generate hydrogen.

Out of stock

Description

What the product is used for

Blue Water 900 can be used to consume hydrogen either through drinking the water or inhaling the gas/hydrogen gas inhaler.

Blue Water 900 generates molecular hydrogen and brings its benefits to a life on the go. Blue Water 900 is perfect to use in the gym, during holidays, on business trips, hiking or any other activity.

Hydrogen rich water

The device enriches drinking water with molecular hydrogen through Proton Exchange Membrane (PEM) electrolysis technology.

  • Operates on mode #1 that is set for 5 minutes
  • H2 concentration is highest with water slightly above room temperature up to 40 C ( 105 F)
  • No contraindications or side effects
  • Only drinking filtered or bottled water can be used

Hydrogen inhalation

Hydrogen inhalation gives the option to consume larger quantities of molecular hydrogen in comparison to hydrogen rich water. 10 minutes of hydrogen inhalation is equal to drinking 2 liters of hydrogen rich water.

  • Hydrogen inhalation is carried out through an inhalation nozzle and a nasal cannula
  • Continuous supply of molecular hydrogen (H2)
  • Hydrogen gas inhaler operates on mode #2 that is set for 20 minutes
  • Repetition of cycles achieves the best results
  • Delivers larger quantities of molecular hydrogen in the body
  • Combination of hydrogen inhalation with drinking hydrogen rich water achieves the best results
  • No contraindications or side effects
  • Works with filtered and unfiltered water

What technology the product uses

Blue Water 900 uses electrolysis technology with PEM (Proton Exchange Membrane) to generate water enriched with pure molecular hydrogen of high concentrations 0.9 – 1.2 ppm and hydrogen gas of over 20,000 ppm in 20 mins. By utilizing PEM technology, electrolysis by-products such as oxygen, ozone, and chlorine do not enter the water. Blue Water 900 generates a high concentration of hydrogen, regardless of the presence of minerals in the water. No filter is required. It works perfectly with bottled, filtered, RO (Reverse Osmosis) and distilled water.

How to operate the product

The device has a display with one on/off button and two operational modes: mode #1 – 3 minutes and mode #2 – 5 minutes. Mode #1 is used for generation of hydrogen rich water, while mode #2 is used for hydrogen inhalation/hydrogen gas inhaler. Pressing on/off button starts or stops the hydrogen generation cycle. Pressing the on/off button twice starts the 3-minute mode of generating hydrogen rich water. Pressing on/off button 3 times starts the 5-minute mode for hydrogen inhalation. Blue illuminating light and generation of small bubbles confirms the working status of the device. The voice indicator informs about the start and end of the hydrogen generation cycle (it can be muted).

How to charge the product

Blue Water 900 runs on long lasting lithium battery. Battery indicator on the display shows the state of the battery charge. Full charge allows to use the device for about 28-30 cycles of 3 minutes (mode #1) and 7-8 cycles of 5 minutes (mode #2). The device is charged with a standard USB cable providing great flexibility particularly when travelling including charging through a laptop USB port.

What the product display includes

The modern electronic display of Blue Water 900 includes: – Two operating modes: mode #1 – 3-minute for generating hydrogen rich water, mode #2 – 5-minute for hydrogen inhalation. – Battery charge level indicator – Hydrogen generation status (on: eliminated running bubbles/ off: no bubbles) – A voice signal in four languages: English, Chinese, Japanese, Korean. The beginning and completion of the hydrogen generation cycles will be spoken in the chosen language. The voice signal can be muted.

What the water adapter is used for 

Blue Water 900 comes with a water bottle adapter. It is designed to allow conventional water bottles (glass or plastic) to attach directly to the base of the device. This makes Blue Water 900 more compact. During hydrogen generation process molecular hydrogen saturates water with the same levels as when the device bottle is used (hydrogen concentrations of 0.9 -1.2 ppm).

Some Specifications of the Blue Water 900

A stylish bottle design makes Blue Water 900 a fashionable accessory.

  • Electrolysis with Proton Exchange membrane (PEM)
  • Electrode: Platinum and Titanium plated
  • Bottle volume: 500 ml
  • Materials: Tritan, MSDS (Body, Base), BPA free
  • Device dimensions: 272 (H) x 75 (D1) x 65 (D2) mm
  • Device weight: 400 g
  • Powered by long lasting Lithium Polymer built-in battery
  • Timer: 3 (for H2 water generation) and 5 minutes (for H2 inhaling)
  • H2 water concentration: 0.9-1.2 ppm (varies with water quality and temperature)
  • H2 gas concentration: over 20,000 ppm in 20 mins (4 repeated 5 min sessions)
  • H2 flow rate: 4 ml/min
  • Oxidation Reduction Potential (ORP): up to -300 mV
  • pH 7-8
  • For use only with filtered/bottled water
  • Power supply: AC100 – 240V / 50-60 Hz / DC 5V, 0.3A
  • Battery: DC 3.7 V/ 1600 mAh (lithium polymer battery)

How the product is packed

The device is packed in an elegantly designed box, secured inside with packing foam.

How the product is maintained

Bottle cleaning

Separate the bottle from the base and clean it with water or wipe with a sponge/smooth cotton cloth. Neutral detergent can be used for cleaning. Recommended cleaning frequency: 1-2 times a week. Do not use abrasive cleaning sponges / cloths.

Electrode (bottle base) cleaning

If you use Water minerals cause scale buildup in the hydrogen water generator (bottle base/electrode). This results in lower hydrogen production. To ensure proper functioning of the device, regular cleaning of the electrode is required. Fill the bottle with tap water and add 10-20 ml of vinegar/citric acid into the water. Run the device 2 times on mode #1 (6 min in total). Wash the bottle once the hydrogen generation is completed. If you use distilled or reverse osmosis water there is no scale to build up.

How to store the product

If you are not planning on using the product for a long period of time, pour enough water into the bottle to completely cover the hydrogen generator mesh. Keep the bottle in an upright position.

 

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.